Inspection History Details
Inspection Status: Correction Required
Inspection History: INITIAL CODE VIOLATION
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/18/2003 | INITIAL CODE VIOLATION | Correction Required | AFTER INFO FROM CAPT HERRERA VERIFIED ELECTRIC AND GAS METER WERE OFF WAITED IN ORDER TO ENTER RESIDENCE TO ASSES DAMAGE DUE TO SMOKE. AFTER INSPECTION WROTE DAMAGE REPORT AND VERIFIED RESPONIBILITY TO OWNER FOR SECURING HOUSE. SEE ATTACHED DAMAGE REPORT. CAUSE OF DAMAGE: FIRE LOCATION OF DAMAGE: ORIGINATED REAR NORTH ROOM POSSIBLY AT SUB PANEL. BUILDING: NORTH TWO ROOMS CIELING FRAMING CHINGED BADLY WALL FRAMING NW ROOM COMPLETE BURNED QUITE ALOT OF SHEET ROCK ON CIELINGS. ELECTRICAL: MAIN DISCONNECT TO SUBPANEL INCORRECTLY WIRED SUB PANEL BADLY WIRED, CIR TIED INTO CB DIRECTLY THUR FRONT NO COVER, OPEN SPLICES SEVERAL LIGHTS THRU OUT - RESIDENCE NEEDS COMPLETE RE WIRE. PLUMBING FACIAL SW SHUT GAS METER WILL NEED A PERMIT AND PRESSURE TEST. MECHANICAL: FACIAL WILL NEED PERMIT FOR OCCUPANCY. SUMMARY OF REMARKS SOME ROOMS DID NOT APPEAR FINISHED, NO SHEET ROCK AT CIELINGS IN TWO ROOMS. |