Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL02161
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/05/2004 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/ CORRECTIONS MADE OK. UCC LEFT AT METER. S.W. GAS 889-1888 | |
12/30/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) MUST REMOVE UNIONS IN LINE NEW AND EXISTING AND REPLACE WITH RIGHT AND LEFT HAND NIPPLES. 2) MUST PROVIDE AN ENCLOSURE FOR WTR HTR WHEN LOCATED OUTDOORS. 3) MUST REPLACE T&P VALVE AND PROVIDE A DRAIN AND TERMINATE 6" A.F.F. 4) RE-TEST SYSTEM - 10 LBS MIN. |