Permit: T03PL02136

Parcel: 110060820

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/28/2004 PLUMBING - FINAL Approved 1) UNIT #3 IS OK AIR ADMITANCE VALVE HAS BEEN INSTALLED. 2) NOTE #4 TRAP ARM CANNOT BE HIGHER THAT EXSISTING TRAP ARM
05/04/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
04/16/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*
02/20/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 3005 - WTR TEST ON UNDERGROUND 3" SEWER APPROVED FOR KITCHEN SINKS AT UNITS 1-4./ 3050- 15 PSI TEST FOR UNIT 1 FROM STUB FOR METER TO EXISTING STOVE, POSSIBLE FUTURE WTR HTR OK. UNIT 2, 15 PSI TEST FROM METER STUB TO FUTURE FURNACE CAPPED, WTR HTR AND STOVE LOCATION CAPPED OK. UNIT 3 - 15 PSI TEST FROM METER STUB TO DRYER OK AND STOVE LOCATION CAPPED. UNIT 4 - 15 PSI TEST FROM METER STUB TO WTR HTR LOCATION CAPPED OK. / 3035 - H2O PIPING OK TO COVER IN GROUND. / 1) WILL NEED TO SEE RUN TEST AT UNITS 2-4 FOR KITCHEN DRAIN WITH STUDDER VENT INSTALLATION. 2) HAVE WTR HTR FOR UNIT 2 ADDED TO PERMIT. 3) WTR HTR AT UNIT 2 AND 4 TO BE IN WEATHER PROOF ENCLOSURE.
12/23/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE PROVIDE PERMIT FOR SEWER, WASTE AND VENT AND H20 PIPING OR HAVE THIS ADDED TO PERMIT. 2) PROVIDE GAS ISOMETRIC FOR BLDG CITY APPROVED AND ADDITIONAL FUTURE GAS. 3) PLEASE SEE 94 UPC - 1211.5 FOR PIPING. 4) PLEASE HAVE LICENSED CONTRACTOR DO WORK.