Permit: T03PL02021

Parcel: 137051820


Addresses:

744 W NEVADA ST #03

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/12/2003 PLUMBING - GAS PRESSURE TEST Approved
12/10/2003 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*
12/08/2003 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*
12/04/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/ 1) MUST ANCHOR ½" GAS SUPPLY TO WTR HTR. 10 MIL. TAPE NOT ACCEPTABLE. 2) MUST REMOVE SINGLE WALL FLU VENT AND REPLACE WITH DBL WALL 'B' VENT AND CAP THRU ROOF FOR WTR HTR. 3) MUST PROVIDE WTR HTR ENCLOSURE. 4) MUST HARD PIPE ½" GAS SUPPLY INTO WALL FURNACE HOUSING THEN CONNECT FLEX CONNECTOR.