Permit: T03PL02002

Parcel: 118035320


Addresses:

2747 W SHERYL DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/03/2003 PLUMBING - FINAL Approved 1) GAS PRESSURE TEST IS OK 2) WATER HEATER FLUE VENT, T & P, VALVE AND DRAIN OK 3) GAS PACK ON ROOF IS OK 4) OK TO BACKFILL TRENCH
12/02/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) GAS PRESSURE TEST WAS BELOW 10 LBS MIN. 2) MUST REMOVE FLEX LINE ON T&P DRAIN AND RUN FULL SIZE 3/4" DRAIN. 3) MUST PROVIDE ANOTHER 10X10 LOUVER GRILL ON WATER HTR DOOR 12" BELOW CEILING. 4) MUST SEAL GAS LINE PENETRATION AT REAR OF HOUSE.