Permit: T03PL01968

Parcel: 110073600


Addresses:

2438 N FAIR OAKS AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/01/2003 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
11/26/2003 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000* REMOVE GAS LINE FROM UNDERGROUND UNDER CARPORT RUN OVERHEAD. HAND PIPE THROUGH WALL OF FURNACE.(EXTEND VENT ON WATER HEATER.)
11/25/2003 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000* 1) PIPING AT NORTH SIDE OF HOUSE TO BE MIN 6" ABOVE FINISH GRADE. 2) ALL APPLIANCES TO HAVE AGA OR CSA APPROVED GAS VALVES. 3) PLEASE PROVIDE PERMIT FOR WATER HEATER AND PIPE TEMPERATURE PRESSURE RELIEF TO 6" FROM FINISH GRADE. 4) GAS PIPING TO BE COMPLETED INTO WATER HEATER ENCLOSURE WITH OUT UNION. 5) SECURE WITH 3 SCREWS EACH JOINT FOR WATER HEATER FLUE PIPING AND THEN TAPE.