Permit: T03PL01920

Parcel: 138231380


Addresses:

601 W ELVIRA RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/28/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR FLU VENT, T&P VALVE AND DRAIN OK. 4) FURNACE FLU VENT IS OK.
11/25/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999* NO ONE HOME
11/19/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST PROVIDE ROOF FLASHING FOR ALL PENETRATIONS ON ROOF. 2) MUST SCREW DOWN VENT CONNECTOR FOR WATER HTR WITH (3) SHEET METAL SCREWS PER JOINT AND @ APPLIANCE COLLAR. 3) MUST HARD PIPE THRU FURNACE HOUSING THEN CONNECT FLEX CONNECTOR. 4) MUST RUN FULL SIZE 3/4" T&P DRAIN AND PROVIDE NEW T&P VALVE. NOTE: TEMP PROBE MUST EXTEND INTO TANK MIN. 2" 5) MUST PROVIDE NEW AGA OR CSA GAS SHUT OFF VALVES AT ALL APPLIANCES. 6) RETEST SYSTEM.