Permit: T03PL01875

Parcel: 116213110


Addresses:

122 S CUESTA AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03PL01875

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/21/2004 PLUMBING - FINAL Approved 1) SOIL WATER TEST FOR RAIN HEADERS IN BLDG. J LEVEL P-1 BETWEEN COLUMN YY AND XX AND GRID 27, TO 28 AS NOTED ON PLAN 2) SOIL WATER TEST FOR WASTE AND VENT SYSTEM BLDG C P-2 LEVEL EAST SIDE OF WING
01/16/2004 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*
01/15/2004 PLUMBING - FINAL Not ready for Inspection CODE VIOLATION ON WATER HEATER VENT NOT TO CODE. PROVIDE PROPER CLEARANCE ON SINGLE WALL. REMOVE DRYER VENT FROM WTR HTR. READ OVER ALL REQUESTS FROM LAST INSP. MAKE ALL CORRECTIONS AND CALL AGAIN FOR INSP.
11/28/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE BOND GAS LINE. 2) FLUE VENT FOR WATER HTR AND WALL HTR TO EXTEND 3' ABOVE COOLER. 3) PLEASE HARD PIPE THRU WALL, PROVIDE AGA OR CSA APPROVED GAS VALVE AND FLEX TO WALL HTR.
11/26/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST REMOVE AND REPLACE T&P VALVE. 2) MUST CUT OFF THREADS AT END OF T&P DRAIN. 3) MUST HARD PIPE GAS LINE TO WALL FURNACE. 4) MUST LOCATE SHUT OFF VALVE UPSTREAM OF FLEX CONNECTOR. 5) MUST SCREW DOWN WTR HTR FLU VENT WITH [3] SHEET METAL SCREWS PER JOINT. 6) RE-TEST ENTIRE SYSTEM.