Permit: T03PL01857

Parcel: 137100610


Addresses:

5440 S 13TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/24/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WTR HTR T&P VALVE, FLU VENT OK. 4) FURNACE FLU VENT OK.
11/17/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/
11/10/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) BLACK PIPE UNDERGROUND TO BE WRAPPED. 10 MIL. PVC TAPE WITH 1/2 WRAP OVERLAP PRIMED WITH GAS PIPE PRIMER. 2) MUST HAVE AGA OR CSA APPROVED VALVE INSTALLED BEFORE UNION. 3) TURN OFF ALL APPLIANCES AND AIR TEST TO TEN POUNDS.