Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 12/23/2003 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 12/19/2003 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*/ PROVIDE A MIN 10 POUND PRESSURE TEST ON GAS SYSTEM. 2) REMOVE WATER LINE RUNNING UP TO ROOF THRU FLUE VENT. 3) INNER SLEEVE FROM DOUBLE WALL VENT PIPE THRU ROOF IS COMING APART FROM INSIDE VENT PIPE. REPLACE UPPER SECTION OF VENT PIPE. RE CALL FOR INSP. |
| 11/18/2003 |
PLUMBING - GAS PRESSURE TEST |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) ALL APPLIANCES TO HAVE APPROVED GAS VALVES 2) ALL VENTS WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE COOLER 3) COOLER WATER SUPPLY CANNOT BE RAN IN WATER HEATER VENT PIPING 4) GAS PIPING AT WATER HEATER TO BE SUPPORTED PROPERLY |
| 11/14/2003 |
PLUMBING - GAS PRESSURE TEST |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ PLEASE HAVE SOMEONE HOME AT TIME OF NEXT INSPECTION. |