Permit: T03PL01827

Parcel: 128061730


Addresses:

6044 E 20TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/23/2003 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
12/19/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/ PROVIDE A MIN 10 POUND PRESSURE TEST ON GAS SYSTEM. 2) REMOVE WATER LINE RUNNING UP TO ROOF THRU FLUE VENT. 3) INNER SLEEVE FROM DOUBLE WALL VENT PIPE THRU ROOF IS COMING APART FROM INSIDE VENT PIPE. REPLACE UPPER SECTION OF VENT PIPE. RE CALL FOR INSP.
11/18/2003 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ 1) ALL APPLIANCES TO HAVE APPROVED GAS VALVES 2) ALL VENTS WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE COOLER 3) COOLER WATER SUPPLY CANNOT BE RAN IN WATER HEATER VENT PIPING 4) GAS PIPING AT WATER HEATER TO BE SUPPORTED PROPERLY
11/14/2003 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*/ PLEASE HAVE SOMEONE HOME AT TIME OF NEXT INSPECTION.