Permit: T03PL01821

Parcel: 128060370


Addresses:

5850 E 21ST ST


Inspection Status: Closed

Inspection History: PLUMBING - FINAL

Permit Number - T03PL01821

Inspection Description - PLUMBING - FINAL

Inspection Status - Closed

Date Description Inspector Results Comments
02/14/2008 PLUMBING - FINAL Closed GAS CARD LEFT 11/07 FOR APPROVAL OF GAS PIPING. HOME ADDITION DONE T06CM02911 FOR APPROVAL OF OTHER PLUMBING ITEMS.
11/07/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ PLEASE PROVIDE DRAIN TO WITHIN 6" OF FLOOR FOR TEMP AND PRESSURE RELIEF VALVE AT INTERIOR WATER HEATER. NO THREADS ON OUTLET END. GAS CARD DROPPED AT METER.
11/06/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE PROVIDE 10 PSI AIR TEST ON ENTIRE SYSTEM. 2) ALL UNDERGROUND PIPING TO BE SCOTCH COATED OR PRIMED AND TAPED. 3) PROVIDE AGA OR CSA APPROVED VALVE AT ALL APPLIANCES. 4) EXTERIOR WATER HEATER TO HAVE VENT CONNECTED AND SECURED PROPERLY. 5) EXTERIOR WATER HEATER TO BE INSTALLED IN WEATHER PROOF ENCLOSURE. 6) PLEASE PROVIDE ACCESS TO ROOF FOR PIPING INSPECTION.
11/04/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE PROVIDE ACCESS TO ENTIRE GAS SYSTEM AT TIME OF NEXT INSPECTION. 10:30 AM 2) PLEASE PROVIDE 10 PSI TEST ON ENTIRE GAS SYSTEM