Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/04/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 10/31/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) 20 PSI TEST IS OK 2) SECURE GAS LINE FOR WATER HEATER 2) PROVIDE A DRAIN ON T & P RELIEF VALVE 3) PROVIDE MINIMUM 3 SCREWS IN VENT CONNECTOR 4) PROVIDE MINIMUM 1" CLEARANCE AROUND WATER HEATER VENT FROM COMBUSTIBLES 5) PROVIDE HIGH AND LOW COMBUSTION AIR VENTS TO WATER HEATER ROOM 6) PROVIDE APPROVED VENT CAPS ON WATER HEATER VENT AND FURANCE VENT. EXTEND FURNACE VENT 2' ABOVE EVAP COOLER RECALL FOR INSPECTION |