Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/20/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE OK 2) OK FOR GAS 3) UCC LEFT AT METER |
| 10/16/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) PETITION OF APPEAL SPECIFIES THAT THE T&P RELIEF DRAIN BE PIPED TO THE PAN. CURRENTLY THE DRAIN TERMINATES APPROX. TWO INCHES FROM THE VALVE WITH THREADS, WHICH ARE NOT PERMITTED. 2) PRESSURE RELIEF VALVE OUTSIDE, ALSO TERMINATES WITH THREADS, THIS IS NOT PERMITTED. 3) ALL GAS PIPING IS TO BE AT LEAST 6" ABOVE GRADE. GAS PIPING ON THE FLOOR IS NOT PERMITTED. |