Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03PL01695

Parcel: 133311350


Addresses:

8800 E MCCLELLAN ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/20/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) ALL CORRECTIONS MADE: 10 PSI TEST OK FROM METER TO FURNACE AND WATER HEATER. GAS CARD DROPPED AT METER
10/17/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PROVIDE APPROVED COUPLING NOT THREAD PROTECTOR. FOR COUPLING PIPE. 2) PLEASE HAVE ALL UNDERGROUND PIPING PRIMED AND WRAPPING AT JOINTS AND TOOL MARKS. 3) PLEASE PROVIDE PROPER FLASHING AT ROOF PENETRATION.