Permit: T03PL01688

Parcel: 134260330


Addresses:

618 S STANFORD PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/28/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 10 PSI GAS PRESSURE TEST IS OK FROM METER TO WATER HEATER AND GROUND MOUNTED EXTERIOR UNIT. ALL CORRECTIONS MADE.
10/24/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) PLEASE PROVIDE #18 INSULATED TRACER WIRE WITH PL5 UNDERGROUND PIPING TERMINATEING 12" ABOVE GROUND ON EACH END 2) ALL ABOVE GROUND PIPING SHALL BE 6" MINIMUM FROM FINISHED GRADE 3) PLEASE CHECK FOR PROPER GROUNDING OF GAS SYSTEM. RETEST PIPING AND CALL FOR REINSPECTION
10/22/2003 PLUMBING - FINAL Denied IVRS - Inspection 0920*/ PLEASE CALL FOR AN INSPECTION WHEN SOMEONE WILL BE HOME.