Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03PL01686

Parcel: 117080550


Addresses:

808 S 4TH AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/05/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) WATER HTR FLU VENT, T&P VALVE AND DRAIN IS OK.
11/04/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) CAN NOT HAVE ANY UNIONS IN LINE. MUST USE RIGHT - LEFT HAND NIPPLES, SEE SEC. 1211.10 94 UPC. 2) MUST REMOVE ALL THREAD PROTEDTOR COUPLING IN LINE AND REPLACE WITH APPROVED COUPLINGS. 3) MUST SCREW DOWN FLU VENT FOR WATER HEATER WITH (3) SHEET METAL SCREWS PER JOINT AND AT APPLIANCE COLLAR. 4) MUST EXTEND WATER HEATER FLU VENT 3' ABOVE COOLER WHEN VENT IS LOCATED WITHIN 10' OF COOLER. 5) RE-TEST THE SYSTEM 10 LBS MIN.