Permit: T03PL01685

Parcel: 122070690


Addresses:

4445 E WAVERLY ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/15/2003 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*/ 10 PSI TEST IS OK. ALL CORRECTIONS HAVE BEEN MADE. LEFT GAS CARD
10/13/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/ 1) PROVIDE A DRAIN LINE ON T&P VALVE. 2) CRIMPED ENDS OF WATER HEATER VENT MUST GO WITH AIR FLOW. REPLACE ASBESTOS VENT WITH DOUBLE WALL PIPE. PROVIDE MIN. 3 SCREWS IN JOINTS OF VENT CONNECTOR. PROVIDE AN ENCLOSURE AROUND WATER HEATER. BE SURE TO HAVE MIN. 1" CLEARANCE FROM COMBUSTABLES ON DOUBLE WALL VENT. REMOVE UNION FROM GAS LINE ON ROOF AND USE REVERSE THREAD COUPLING AND NIPPLE. RETEST SYSTEM. RECALL FOR INSPECTION.