Permit: T03PL01665

Parcel: 115041960


Addresses:

615 E HELEN ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/02/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
10/30/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) ABS REQUIRES AT LEAST 12" OF COVER. 2) ABS MAY NOT BE INSTALLED IN EXPOSED EXTERIOR LOCATIONS. 3) A VENT MUST RISE VERTICALLY AT LEAST 6" ABOVE OVERFLOW OF FIXTURE BEFORE OFFSETTING HORIZONTALLY. 4) DRAIN MUST HAVE 1/4" PITCH PER FOOT. 5) A SANTEE MAY NOT BE INSTALLED IN A HORIZONTAL POSITION.