Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/12/2003 | PLUMBING - GAS PRESSURE TEST | Approved | ||
| 12/03/2003 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection 0000*/ CALL IN ALL INSPECTIONS! > BECAUSE OF THE AMOUNT AND SIZE OF AGGREGATE IN NATIVE SOILS, SHADE GAS PIPE WITH SAND OR CLEAN FILL. I WANT TO SEE THIS. > SEE 313.8 94 UPC - FLASH ALL PENETRATIONS THRU ROOF. > SEE 1211.8 94 UPC - SUPPORT OF GAS PIPING ALSO TABLE 3-1. > WALL FURNACES TO BE SECURED TO THE WALL. > INSTALL ALL VALVES, MAKE ALL CONNECTIONS. > SEE 1212.0 SIZE OF APPLIANCE CONNECTORS. > PLEASE HAVE PLBR ON SITE AT TIME OF NEXT INSPECTION. > FLEX CONNECTOR MAY NOT PASS THRU WALL OR PARTITION. > TERMINATION OF T&P RELIEF DRAIN. > VENT FOR WTR HTR NOT APPROVED. |
|
| 11/05/2003 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999*/ 1) I NEED AN APPROVED DRAWING SHOWING DEVELOPED LENGTH AND BTU CONSUMPTION. 2) SEE 509.0 94 UPC LOCATION OF WATER HEATER PLUS NO T&P RELIEF DRAIN. 3) SEE 1211.3 INSTALLATION OF GAS PIPING. 4) SEE TABLE 3-1 94 UPC SUPPORT OF GAS PIPING. 5) SEE 1211.10 94 UPC UNIONS. 6) SEE 1212 94 UPC APPLIANCE CONECTORS. 7) PLEASE CHECK ALL WORK FOR ANY ADDITIONAL CORRECTIONS THAT NEED TO BE DONE. |