Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL01645
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/ 1) CORRECTIONS MADE OK. 2) AZ MAINTENANCE COMPANY CHECKED OUT FURNACE 3) OK FOR GAS 4) UCC LEFT AT METER | |
| 10/17/2003 | PLUMBING - FINAL | Not ready for Inspection | 1) GAS PRESSURE TEST OK. CORRECTIONS MADE OK. 2) PROVIDE CERTIFICATION OF FURNACE. | |
| 10/06/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) PLEASE PROVIDE 10 LBS TEST ON COMPLETE SYSTEM. 2) CODE VIOLATION ON WATER HEATER. INSTALL PROPER VENT. PROVIDE WORKING RELIEF LINE WITH PROPER DRAIN. WATER HEATER NOT IN WORKING ORDER AT THIS TIME. WATER HEATER TOO POOR OF CONDITION TO REPAIR. HAVE YOUR PLUMBER PROVIDE PROPER PERMITS TO REPLACE / REPAIR ROT IN FLOOR. PROVIDE PROPER COMBUSTION AND RELIEF AIR. FURNACE NOT COMPLETE - PLEASE PROVIDE CERTIFICATION BY MECH. CONTRACTOR THAT FURNACE IS IN GOOD WORKING ORDER. |