Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL01560
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/01/2003 | PLUMBING - FINAL | Approved | 1) CORRECTIONS MADE OK. T&P RELIEF DRAIN TO OUTSIDE OK. 2) OK FOR GAS. 3) UCC LEFT AT METER.S.W. GAS 889-1888. | |
09/30/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) T&P RELIEF DRAIN MAY NOT GO UP THRU THE ROOF-MUST BE GRAVITY DRAIN 2) T&P VALVE MUST HAVE PROBE INTO TANK, PRESSURE VALVE NOT APPROVED | |
09/29/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/1) PRESSURE TEST OK. PIPING OK. 2) INSTALL ALL APPROVED VALVES AND MAKE ALL CONNECTIONS FOR FINAL INSPECTION. 3) WATER HEATER REQUIRES T&P RELIEF VALVE AND DRAIN. |