Permit: T03PL01487

Parcel: 120081070


Addresses:

313 W MACARTHUR ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/03/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK. 2) GAS SHUT OFF VALVES OK. 3) ALL CORRECTIONS HAVE BEEN MADE.
10/15/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST PROVIDE AIR PRESSURE TEST OF 10 LBS MIN. AT TIME OF INSPECTION. 2) MUST REPLACE GAS SHUT OFF VALVES FOR KITCHEN RANGE AND WATER HEATER WITH AGA OR CSA VALVES. 3) T&P DRAIN FOR WATER HEATER CAN NOT HAVE FLEX LINE. 4) T&P DRAIN MUST TERMINATE 6" ABOVE GRADE POINTED DOWNWARD. 5) PROVIDE DOOR FOR WATER HEATER ENCLOSURE.