Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL01475
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* | |
| 09/24/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/1) STILL NO PRESSURE TEST 2) PLEASE CONNECT ALL APPLIANCES DO NOT TEST THRU VALVES. 3) STILL NO COMBUSTION RELIEF. T&P RELIEF VALVE NOW DISCHARGING CONTINUOUSLY THIS INSPECTOR DID NOT TOUCH RELIEF VALVE. 4) INSPECTOR DID NOT ENTER RESIDENCE - PLEASE HAVE ALL CONNECTIONS MADE BEFORE CALLING FINAL. | |
| 09/23/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/1) NO TEST ON SYSTEM REQUIRED 10# MINIMUM. 2) SCOTCH COAT PIPING IS FOR UNDERGROUND USE. ABOVE GRADE PIPING IS TO BE AT LEAST 6" ABOVE GRADE. 3) PIPE PENETRATION THRU ROOF TO BE FLASHED. 4) INSTALL ALL APPROVED VALVES AND FLEXES. 5) NO T&P RELIEF DRAIN ON WATER HEATER. 6) NO COMBUSTION RELIEF FOR WATER HEATER. INSPECTION STOPPED - THIS MAY NOT BE A COMPLETE LIST . HAVE YOUR PLUMBER CHECK ALL WORK. |