Permit: T03PL01449

Parcel: 107112930


Addresses:

3067 N 2ND AV #03

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/10/2003 PLUMBING - FINAL Approved
11/05/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) THE WORK HERE GOES WAY BEYOND A SIMPLE GAS RECONNECT. THERE HAS BEEN A LOT OF REPAIR DUE TO FIRE DAMAGE, INCLUDING PLUMBING REPLACEMENT, WHICH WAS COVERED WITHOUT INSPECTION. 2) THE WATER HEATER HAS BEEN RELOCATED WITHOUT PERMITS. SOME CORRECTIONS WOULD BE - IMPROPER VENTING, COPPER CONNECTED TO GALVANIZED AND UNAPPROVED GAS COCK. I WILL REQUIRE AN APPROVED DRAWING FOR THE INTER-CONNECTION OF DOMESTIC HOT WATER AND HEATING SYSTEM. 3) INSTALL GAS VALVE AND PLUG AT STOVE LOCATION. 4) REQUIRE MIN. 10 POUND AIR TEST. 5) SECURE ALL REQUIRED PERMITS AND EXPOSE ALL COVERED WORK - CALL FOR INSPECTION THEN CALL FOR GAS.
09/08/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/1) NOBODY HOME. 2) NO TEST ON SYSTEM. 3) WAS A PERMIT SECURED FOR NEW WATER PIPING AT SERVICE?