Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
12/03/2003 PLUMBING - GAS PRESSURE TEST Approved
12/02/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
11/28/2003 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection 0000*
11/21/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
08/27/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/ 1) MUST PROVIDE AIR PRESSURE TEST ON ENTIRE SYSTEM AT TIME OF INSPECTION. 2) CAN NOT HAVE ANY UNIONS IN GAS LINE. MUST USE RIGHT AND LEFT HAND NIPPLES. 3) MUST EXTEND T&P DRAIN AND TERMINATE 6" ABOVE FLOOR. 4) MUST REPLACE ALL GAS SHUT OFF VALVES WITH AGA OR CSA APPROVED VALVES. 5) MUST STRAP DOWN 1/2" GAS LINE TO WALL FOR WATER HTR.