Permit: T03PL01384

Parcel: 140322190

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T03PL01384

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
09/03/2003 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK 2) GAS SHUT OFF VALVES OK 3) WATER HEATER FLUE VENT, T & P VALVE AND DRSIN IS OK 4) FURNACE FLUE VENT IS OK
08/29/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/ SEE NOTES # 1&2 AS REQUESTED FROM LAST INSP. DATED 08/26/2003
08/26/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/1) MUST PROVIDE A 10X10 LOUVER GRILL LOCATED 12" BELOW CEILING FOR WATER HEATER COMBUSTION RELIEF. 2) MUST PROPERLY SEAL AND VENT SLEEVE FOR EXISTING GAS LINE UNDER SLAB AND PORCH. 3) MUST HARD PIPE FURNACE THRU APPLIANCE HOUSING SEE SECTION 1212.0 SUB NOTE #2 - 94 UPC.