Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL01344
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/21/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/1) WATER HTR INSTALLATION IS OK. 2) ALL CORRECTIONS HAVE BEEN MADE. | |
08/19/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/1) FLU VENT CONNECTOR REQUIRES (3) SHEET METAL SCREWS PER JOINT. 2) ENCLOUSURE REQUIRES 2 10X10 LOUVER GRILLS FOR COMBUSTION RELIEF LOCATED 12" ABOVE FLOOR AND 12" BELOW CEILING. |