Permit: T03PL01301

Parcel: 117031590


Addresses:

850 N 11TH AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03PL01301

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/21/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/1) 15# AIR TEST ON GAS SYSTEM OK. 2) OK TO BACKFILL. 3) CORRECTIONS MADE OK. 4) UCC LEFT AT METER. / METER PINNED - ONLY SECTION OF GAS THAT HAD A LEAK WAS REPLACED./ SW GAS 889-1888
08/14/2003 PLUMBING - FINAL Denied 1) PLEASE HAVE A PRESSURE TEST OF AT LEAST 10# ON THE SYSTEM AT THE TIME OF INSPECTION.
08/13/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/1) PLEASE USE THE CORRECT GUAGES. TESTS OF LESS THAN TEN POUNDS SHALL USE GUAGES IN 1/10 POUND INCRIMENTATION. TESTS BETWEEN 10 LBS AND 100 LBS SHALL BE WITH GUAGES IN ONE POUND INCRIMENTATION OR LESS. 2) CONNECT GAS PIPING FROM STOVE TO REST OF SYSTEM AND RE-TEST. 3) STOVE MISSING APPROVED VALVE AND FLEX CONNECTION.