Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/08/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST IS OK 2) GAS SHUT OFF VALVES OK 3) WATER HEATER FLU VENT, P & T VALVE AND DRAIN IS OK 4) FURNACE FLU VENT OK 5) OK TO BACKFILL TRENCH |
| 08/06/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1) MUST REMOVE THREAD PROTECTORS IN GAS LINE UNDERGROUND AND REPLACE WITH APPROVED COUPLINGS. 2) MUST APPLY TAPE PRIMER (YELLOW) THEN APPLY 10 - MIL TAPE TO JOINTS UNDERGROUND AND WRENCH MARKS. 3) MUST PROVIDE AIR PRESSURE TEST OF 10 LBS MIN @ TIME OF INSPECTION. 4) MUST HARD PIPE THROUGH FURNACE HOUSING THEN CONNECT FLEX CONNECTOR. 5) REPLACE FURNACE GAS VAVLE WITH AGA OR CSA GAS SHUT OFF VALVE. |