Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/22/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) CORRECTIONS MADE OK. 2) OK FOR GAS. 3) UCC LEFT AT METER. / SW GAS 889-1888 |
| 08/15/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) TAPING IS REQUIRED ON FITTINGS AND THOSE SECTIONS OF PIPE STRIPPED FOR THREADING OR MARRED BY WRENCHES. ALL MARRED AREAS REQUIRE TAPE. 2) ROOF TOP GAS TO BE INSTALLED PER TABLE 3-1 94WPC (REQUIRED SUPPORT) 3) REMOVE ROOFTOP UNION AND RE-PLUG LINE. 4) FURNACE VALVE TO BE LOCATED ON THE OUTSIDE OF THE APPLIANCE. REMEMBER A FLEX CONNECTOR MAY NOT PASS THRU A WALL OR PARTITION. |