Permit: T03PL01266

Parcel: 130100420


Addresses:

3110 E 23RD ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/12/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
08/06/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST HAVE DOUBLE WALL FLU VENT THRU CEILING THEN VENT CONNECTOR CAN BE SINGLE WALL. 2) HOT AND COLD SUPPLYS NOT CONNECTED. 3) PROVIDE A AGA OR CSA GAS SHUT OFF VALVE. 4) MUST PROVIDE A 90 DEGREE FITTING @ T&P TERMINATION. 5) SEAL T&P PENETRATION. 6) MUST PROVIDE (3) SHEET MATAL SCREWS PER JOINT FOR FLU VENT AND APPLIANCE COLLAR.