Permit: T03PL01230

Parcel: 120074100


Addresses:

4323 S LIBERTY AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/01/2003 PLUMBING - FINAL Approved
07/28/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) MUST APPLY TAPE PRIMER THEN 10 MIL. TAPE AROUND ALL JOINTS AND WRENCH MARKS UNDERGROUND. 2) CAN NOT HAVE BUSHINGS IN A CONCEALED LOCATION. MUST USE A 1" X 3/4" X 3/4" TEE. 3) MUST PROVIDE 2- 10X10 LOUVER GRILLS FOR WATER HTR 12" ABOVE FLOOR AND 12" BELOW CEILING. 4) MUST EXTEND T&P DRAIN TO DAYLIGHT. 5) MUST SCREW DOWN WATER HTR FLU VENT WITH (3) SHEET METAL SREWS PER JOINT. 6) MUST PROVIDE GAS GUAGE WITH 1/10 INCREMENTS. 7) MUST LOCATE UNION @ HOUSE CONNECTION DOWNSTREAM OF SHUT OFF VALVE. 8) RE TEST THE SYSTEM 10 LBS MIN. 9) RELOCATE GAS ABOVE GROUND UNDER PORCH 6" ABOVE GROUND.