Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 08/22/2003 |
PLUMBING - GAS PRESSURE TEST |
|
Approved |
IVRS - Inspection 0000* |
| 08/14/2003 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0999*/1) MUST PROVIDE VARIENCE FORM FOR ALTERNATE METHOD OF INSTALLATION OF T&P DRAIN. THIS FORM MUST BE SIGNED BY HOMEOWNER AND CODES ADMINISTRATOR AND COPY OF FORM ON SITE AT TIME OF INSPECTION. 2) MUST PROVIDE A FACTORY PRESET PRESSURE REFIFE(?) VALVE @ 125 PSI. 3) T&P DRAIN CAN NOT CONNECT WITH CONDENSATE DRAIN. 4) MUST PROVIDE (3) SHEET METAL SCREWS PER JOINT FOR WATER HEATER VENT CONNECTOR AND APPLIANCE COLLAR. 5) GAS PRESSURE TEST IS OK. |