Permit: T03PL01227

Parcel: 137100490


Addresses:

765 W DAKOTA DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/30/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) ALL CORRECTIONS HAVE BEEN MADE
07/28/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) WATER HTR FLU VENT IS LOCATED WITHIN 10' OF FORCED AIR INLET (COOLER). THEN B-VENT MUST EXTEND 3'0" ABOVE COOLER SEE SECTION: 517.6 94 UPC. 2) WATER HTR FLU VENT REQUIRES (3) SHEET METAL SCREENS PER JOINT, SEE SECTION 514.2 94 UPC. 3) MUST SEAL PENETRATION OF GAS LINE AND T&P DRAIN AT WALL.