Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL01197
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/28/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* | |
07/24/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000* | |
07/22/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*/ 1) WATER HEATER NOT RATED FOR OUTDOOR USE. REQUIRE AN ENCLOSURE. 2) SEE 1211.3 GAS PIPE MAY NOT BE INSTALLED ON THE GROUND UNDER STRUCTURE PIPING TO BE SUPPORTED TO TABLE 3-1 94 UPC. 3) SEE 1211.13 USE APPROVED VALVES. ALL VALVES TO BE AGA OR CSA APPROVED. 4) SEE 523.3.2 VENT CONNECTOR CLEARANCE. - UPC IAP MO - 5) SEE 517.1 VENT TERMINATION (APPROVED CAP) 6) SEE 608.3 T&P RELIEF DRAINS. 7) MAKE ALL CONNECTIONS AND TEST ENTIRE SYSTEM TO TEN POUNDS. DO NOT TEST THRU APPLIANCES. |