Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 10/02/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ GAS FIRED WATER HEATER INSTALLED OK. |
| 08/06/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) PLEASE ACCEPT MY APOLOGY FOR THE INSPECTION ON 8/4/03. THE IVR WAS DOWN AND I COULD NOT RETRIEVE MY MESSAGES. 2) SEE 507.0 94 UPC REQUIRED COMBUSTION AIR FOR GAS FIRED WATER HEATERS. 3) SEE 514.2 94 UPC SECURING VENT CONNECTORS. 4) THERE IS NO CONNECTION BETWEEN VENT CONNECTOR AND VENT. VENT IS LOOSE IN THE WALL. IS VENT TYPE "B" VENT? IS VENT CAP APPROVED? PLEASE MAKE CORRECTIONS AND RE-CALL FOR INSPECTION. |
| 08/04/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ NOBODY HOME. |