Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/10/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/1) ALL CORRECTIONS MADE. 2) GAS CARD DROPPED AT METER. |
| 08/07/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ MUST USE APPROVED GAS PIPE FOR UNDERGROUND. PLEASE PROVIDE THE TESTING FOR THE PIPE USED. PROVIDE A GAS SHUT OFF VALVE AT UNION OUTSIDE. REMOVE UNION FROM GAS LINE IN WALL. SCHEDULE 40 PVC NOT APPROVED FOR T&P DRAIN. PROVIDE HIGH AND LOW COMBUSTION AIR VENTS TO WATER HEATER ENCLOSURE MIN. 100 SQ. IN. EACH OPENING. PROVIDE A MIN. 10LB TEST ON ENTIRE SYSTEM. RE-CALL FOR INSPECTION. REMOVE THREADS FROM END OF T&P DRAIN PIPE. |