Permit: T03PL01096

Parcel: 128050430


Addresses:

5634 E EASTLAND ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/28/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
07/22/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) 14 PSI 2) MUST USE APPROVED TAP PRIMER ON ALL UNDERGROUND JOINTS 3) SECURE VERTICAL SECTIONS OF GAS PIPE TO WALL 4) PROVIDE HIGH AND LOW COMBUSTION AIR VENTS TO WATER HEATER ENCLOSURE. MINIMUM 100 SQUARE INCHES. EACH OPENING 6) VENT CONNECTOR ON WATER HEATER MUST CONNECT INSIDE THE FLUE VENT. REPLACE TRANSITE VENT PIPE. USE DOUBLE WALL PIPE. RETEST SYSTEM
07/01/2003 PLUMBING - FINAL Denied IVRS - Inspection 0920*