Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/28/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/22/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) 14 PSI 2) MUST USE APPROVED TAP PRIMER ON ALL UNDERGROUND JOINTS 3) SECURE VERTICAL SECTIONS OF GAS PIPE TO WALL 4) PROVIDE HIGH AND LOW COMBUSTION AIR VENTS TO WATER HEATER ENCLOSURE. MINIMUM 100 SQUARE INCHES. EACH OPENING 6) VENT CONNECTOR ON WATER HEATER MUST CONNECT INSIDE THE FLUE VENT. REPLACE TRANSITE VENT PIPE. USE DOUBLE WALL PIPE. RETEST SYSTEM |
| 07/01/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0920* |