Permit: T03PL01023

Parcel: 110081950


Addresses:

2702 N DESERT AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/25/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*/ 1) PSI TEST IS OK 2) CORRECTIONS HAVE BEEN MADE, LEFT GAS CARD
06/23/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/ 1) II PSI TEST-PARTIAL OK TO BACKFILL TRENCH. 1) REMOVE UNIONS FROM GAS LINE AND USE REVERSE THREAD COUPLINGS AND NIPPLES. THE UNION AT THE HOUSE CONNECTION AT TRENCH IS ALLOWED 2) T & P DRAIN MUST GO TO THE OUTDOORS WITH A DOWNHILL SLOPE 3) VENT PIPE ON WATER HEATER MUST HAVE MINIMUM 1" CLEARANCE AT PENETRATION THRU THE ROOF. PROVIDE MINIMUM 3 SCREWS IN FURNACE AND WATER HEATER VENT CONNECTORS. RETEST SYSTEM. RECALL FOR FINAL