Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 06/25/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/ 1) PSI TEST IS OK 2) CORRECTIONS HAVE BEEN MADE, LEFT GAS CARD |
| 06/23/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) II PSI TEST-PARTIAL OK TO BACKFILL TRENCH. 1) REMOVE UNIONS FROM GAS LINE AND USE REVERSE THREAD COUPLINGS AND NIPPLES. THE UNION AT THE HOUSE CONNECTION AT TRENCH IS ALLOWED 2) T & P DRAIN MUST GO TO THE OUTDOORS WITH A DOWNHILL SLOPE 3) VENT PIPE ON WATER HEATER MUST HAVE MINIMUM 1" CLEARANCE AT PENETRATION THRU THE ROOF. PROVIDE MINIMUM 3 SCREWS IN FURNACE AND WATER HEATER VENT CONNECTORS. RETEST SYSTEM. RECALL FOR FINAL |