Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 06/10/2003 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
1) SOIL WATER TEST IS OK 2) HCS CONNECTION IS OK 30 OK TO BACKFILL TRENCH |
| 06/09/2003 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0999*/ 1) CAN NOT HAVE A THREADED FITTING IN A NON-ACCESSIBLE LOCATION. SEE SECTION 316.1.5 INSTALLATION STANDARDS 94 UPC |
| 06/05/2003 |
PLUMBING - SEWER HCS CONNECT |
|
Denied |
IVRS - Inspection 0999*/ 1) MUST PROVIDE WATER TEST ON SYTEM 2) MUST HAVE 2' OF SEPARATION OF BLDG. SEWER FROM CITY WATER MAIN WASTE WATER MANAGEMENT SPECS 3) MUST RUN 4" BLDG. SEWER FROM MAIN INTO PROPERTY LINE 4) MUST SHADE TRENCH IN IT'S ENTIRETY 5) MUST BE A MINIMUM OF 4' OF DEPTH IN RIGHT AWAY |