Permit: T03PL00935

Parcel: 137100770


Addresses:

5465 S ALASKA DR

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/17/2003 PLUMBING - GAS PRESSURE TEST Approved
09/11/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
07/02/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/ 1) MUST CONNECT UNDER GROUND GAS LINE TO EXISTING GAS SYSTEM AT HOUSE AND CONNECT NEW GAS LINE DIRECT TO EXISTING OR PROVIDE A AGA OR CSA SHUT OFF VALVE AT HOUSE CONNECTION 2) CANNOT HAVE A P & T DRAIN WITH ANY KIND OF FLEX LINE. THIS DRAIN MUST BE FULL SIZE 3/4" AND HAVE GRAVITY FLOW. NOT TRAPED WATER 3) RETEST SYSTEM 10 POUNDS MINIMUM 4) OK TO BACKFILL TRENCH