Inspection History: PLUMBING - FINAL

Permit Number - T03PL00865

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/17/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
07/07/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999* 10 PSI TEST IS OK
1)PROVIDE MIN 1" CLEARANCE WHERE WALL HEATER VENT PIPE PENETRATES THE ROOF. 2) CONNECT VENT TO WATER HEATER. PROVIDE MIN 3 SCREWS PER JOINT. 3) PROVIDE T&P DRAIN TO WITHIN 6" OF GROUND. 4) EXTEND WATER HEATER VENT 2' ABOVE ROOF. 5) WALL HEATER VENT CANNOT TRANSITION FROM DOUBLE WALL PIPE TO SINGLE WALL PIPE AT ROOF PENETRATOR. PROVIDE AN APPROVED CAP.