Permit: T03PL00694

Parcel: 116060280


Addresses:

1625 N PAVO PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/24/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*1.) CORRECTION MADE OK.
OK FOR GAS. UCC LEFT AT METER. SW GAS 889-1888.
04/21/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) PRESSURE RELIEF VALVE (SET AT 125# TO BE INSTALLED ON COLD LINE, OUTSIDE AT HOSE BIBB.
04/16/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*PRESSURE TEST OK USE APPROVED BLOCKING AND STAPS ON ROOF TOP PIPING REQUIRED TO USE APPROVED FLASHING AT ROOF PENETRATION.
2.) INSTALL ALL APPROVED VALVES, AND MAKE ALL CONNECTIONS.
3.) WATER HEATER, WHEN RESET, WILL NEED TO BE INSTALLED PER 94 UPC CHAPTER FIRE.
4.) YOU MAY WISH TO SECURE A "PETITION OF APPEAL" TO WAIVE LOCATION OF T & P RELIEF DRAIN. MAY NOT THRU THE ROOF.