Permit: T03PL00647

Parcel: 116162640


Addresses:

1039 N 13TH AV #01

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/14/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*CORRECTION MADE OK
FRONT & REAR BLDG OK FOR GAS.
2.) UCC LEFT AT METER SET, AND AT METER.
04/13/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*SECURE PERMIT FOR NEW WATER HEATER AND HAVE IT INSPECTED AND APPROVED.
2.) NOT HOLDING AIR PRESSURE REAR UNIT.
04/10/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) WHERE UNIONS ARE NECESSARY, USE A RIGHT LEFT NIPPLE AND COUPLING.
2.) ALL VALVES TO BE AGA OR CSA APPROVED.
3.) INSTALL SHUT OFF VALVE WITHIN 3 FEET OF STOVE.
4.) EXTEND VENT AT FRONT HOUSE.
5.) USE APPROVED VENT MAT'L FOR REAR BLDG.
6.) ALL BLK IRON PIPE TO BE AT LEAST 6" AFF.
7.) RETEST TO 10#.