Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/24/2003 | PLUMBING - FINAL | Approved | 1.) GAS PRESSURE TEST IS OK 2.) GAS SHUT OFF VALVES OK 3.) WATER HTR FLU VENT, P & T VALVES & DRAIN. 4.) WALL FURNACE FLU VENT IS OK. |
|
| 04/23/2003 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*MUST REMOVED ALL ASBESTOS FLU VENTS AND INSTALL NEW B-VENTS & CAPS. 2.) MUST PROVIDE ADAQUET COMBUSTION RELIFE FOR ALL WATER HTRS ENCLOSURES. 3.) ALL FLU VENTS MUST TERMINATE AT LEAST 12" ABOVE ROOF. 4.) GAS PRESSURE TEST IS OK. |
|
| 04/17/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) MUST PROVIDE T CAPS FOR ALL WALL FURNACE FLU VENTS. 2.) MUST EXTEND ALL WATER HTR FLU VENTS THAT ARE LOCATED WITHIN 10' OF COOLERS 3' - 0" ABOVE COOLER SEE SECTION: 517.6 94 UPC. 3.) MUST REMOVE UNION IN LINE AND PROVIDE ON RIGHT & LEFT HAND NIPPLE SEE SECTION: 1211.10 94 UPC 4.) MUST PROVIDE VARIANCE FORM AND ACCEPTANCE OF ALTERNATE METHOD FOR P & T DRAIN. BY CITY OF TUCSON AND HAVE FORM ON SITE @ TIME OF INSPECTION. 5.) MUST PROVIDE AGA SHUT OFF VALVES FOR ALL APPLIANCES. 6.) MUST PROVIDE 2 10 X 10 OPENINGS FOR COMBUSTION AIR FOR WATER HTR ENCLOSURE SEE SECTION: 507.3.1. AND TABLE 5-1 94 UPC. 7.) MUST HAVE 1" CLEARANCE FROM COMBUSTIONABLE MATERIAL FOR WATER FLU VENT. |