Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03PL00571

Parcel: 116131880


Addresses:

902 N SILVERBELL RD

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/05/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) T & P RELIEF DRAIN MAY NOT TERMINATE ON THE ROOF MUST BE GRAVITY DRAIN
2.) VENT MATERIAL MUST BE APPROVED (LISTED) TYPE
3.) SINGLE WALL TO HAVE LISTING.