Inspection History: PLUMBING - FINAL

Permit Number - T03PL00531

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/24/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
1.) PRESSURE TEST OK
2.) CONDENSATE DRAIN TO DRYWELL IN PATIO AREA.
3.) OK FOR GAS
4.) UCC LEFT AT METER.
5.) ELECTRIC WATER HEATER REPLACED IN RESTROOM SECURE PERMIT AND HAVE IT INSPECTED
NOTE: WATER CLOSET REQUIRE FEET CLEARANCE INFRONT OF BOWL.
03/23/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) PRESSURE TEST OK
2.) BE SURE AND CHECK GAS PACK COMPLETELY AS YOU MAY HAVE DAMAGED IT BY TESTING 15# THROUGH THE APPLIANCES. THIS IS NOT RECOMMENDED.
3.) STRAP ROOF TAP GAS WITH APPROVED STRAPPING.
4.) ALTHOUGH THEY ARE CLOGGED, AND ROTTLED, YOU MAY NOT TERMINATE CONDENSATE WASTE INTO THE GUTTER, BECAUSE IT TERMINATES ON A BRICK PATIO.
5.) THE ELECTRIC WATER HEATER DEFINITELY NEEDS SOME WORK.