Permit: T03PL00525

Parcel: 138231150

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T03PL00525

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/09/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
04/08/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*DOORS LOCKED AGAIN.
MUST PAY RE INSPECTION FEE BEFORE NEXT INSPECTION.
04/04/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) DOORS LOCKED MUST HAVE ACCESS TO APPLIANCES.
03/25/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) CAN NOT HAVE THREADS AT THE END OF P & T DRAIN AND MUST BE 3/4"
2.) MUST COMPLETE FURNACE DUCT AND SCREW DOWN FURNACE FLU VENT (3) SHEET METAL SCREWS PER JOINT.
3.) MUST CAP OFF GAS VALVE FOR RANGE IF APPLIANCE IS NOT INSTALLED @ TIME OF INSPECTION.
4.) MUST PROVIDE A GAS SHUT OFF VALVE BEFORE THE UNION @ HOUSE CONNECTION.
5.) RE TEST SYSTEM WITH TEST GAGE WITH 1/10 INCREMENTS 10LBS MIN.