Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T03PL00525
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/09/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000* | |
| 04/08/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*DOORS LOCKED AGAIN. MUST PAY RE INSPECTION FEE BEFORE NEXT INSPECTION. |
|
| 04/04/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999* 1.) DOORS LOCKED MUST HAVE ACCESS TO APPLIANCES. |
|
| 03/25/2003 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) CAN NOT HAVE THREADS AT THE END OF P & T DRAIN AND MUST BE 3/4" 2.) MUST COMPLETE FURNACE DUCT AND SCREW DOWN FURNACE FLU VENT (3) SHEET METAL SCREWS PER JOINT. 3.) MUST CAP OFF GAS VALVE FOR RANGE IF APPLIANCE IS NOT INSTALLED @ TIME OF INSPECTION. 4.) MUST PROVIDE A GAS SHUT OFF VALVE BEFORE THE UNION @ HOUSE CONNECTION. 5.) RE TEST SYSTEM WITH TEST GAGE WITH 1/10 INCREMENTS 10LBS MIN. |