Permit: T03PL00500

Parcel: 113020040


Addresses:

1208 E ROGER RD

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/31/2003 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*/ 1) 10 PSI TEST IS OK 2) OK TO BACKFILL TRENCH
08/27/2003 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*/1) WHERE UNIONS ARE NECESSARY, A RIGHT , LEFT NIPPLE AND COUPLING SHALL BE USED. 2) ALL VALVES TO BE AGA OR CSA APPROVED. 3) WATER HEATER REQUIRES AN ENCLOSURE. 4) T&P RELIEF VALVE INOPERABLE. 5) NEED TO SEE THE APPROVED VALVE FOR WATER HEATER. 6) REQUIRE CLEARANCE AROUND DOUBLE WALL VENT. 7) VENT TO EXTEND TO Z' ABOVE ROOF. 8) REQUIRE ACCESS TO BOTH HOUSES. 9) REQUIRE 10# TEST ON ENTIRE SYSTEM.