Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/24/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
1.) GAS PRESSURE TEST IS OK
2.) GAS SHUT OFF VALVES OK
3.) WATER HTR FLU VENT, P & T DRAIN & VALVE IS OK.
03/20/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) MUST PROVIDE AIR PRESSURE TEST ON ENTIRE SYSTEM 10LBS MIN.
2.) MUST PERMATLEY CAP OFF GAS SUPPLY TO ALL APPLIANCES NOT IN USE OR REMOVED.
3.) MUST PROVIDE SAFTEY CABLE FOR OVEN WITH CASTERS.
4.) MUST REPAIR WATER HTR WIRING IN WORKING ORDER.